Two ratings answer different questions
Capacity in kilowatt-hours (kWh) describes energy that can be stored. Power in kilowatts (kW) describes how quickly energy can be delivered or charged. A large-capacity battery with a modest inverter can run small loads for longer but may not supply several large loads together. A home battery storage assessment needs both numbers.
Also distinguish nominal capacity from usable capacity. Manufacturers may reserve part of the cell capacity internally. An owner’s backup reserve is another operating setting, not necessarily the same allowance. Ask which quantity the app and quotation display before subtracting reserve from a figure that may already exclude inaccessible energy.
A hypothetical energy calculation
Assume a system has 10 kWh usable energy when full and an operating policy holds 20% of that usable energy for backup during normal grid-connected use. That leaves 8 kWh for ordinary dispatch: 10 × 0.8. At a steady 2 kW load, 8 ÷ 2 = 4 hours before accounting for losses or other limits. These are invented round numbers for arithmetic, not a product specification.
Why the real runtime will differ
Loads vary, conversion uses energy, capacity changes with conditions and age, and the battery may not begin fully charged. Reserve can behave differently during an outage than while connected to the grid. Do not subtract it twice or assume a particular app’s percentage has the same meaning as another’s. Use manufacturer documentation and an installer’s explanation for your system.
| Load | Assumed running power | Combined implication |
|---|---|---|
| Background loads | 0.5 kW | Alone, demand is modest |
| Cooking appliance | 2 kW | Together with background: 2.5 kW |
| Additional heating load | 3 kW | All together: 5.5 kW |
With a hypothetical 5 kW battery output limit, the 5.5 kW combination exceeds the limit despite having plenty of stored energy. While grid-connected, the grid may supply the difference. During backup, the outcome depends on system protection and design; do not use this table as permission to test overloads.
Starting power and phases matter
Some equipment needs more power to start than to run. Continuous and short-duration output ratings are different, and startup capability needs model-specific checking. A three-phase property also needs a clear explanation of which phases the backup system supplies. The essential-loads backup guide turns these questions into a circuit-planning discussion.
Prepare an appliance-use record
- List which loads need energy after sunset and their typical operating times.
- Identify which loads are essential during an outage rather than merely convenient.
- Record ratings from manuals or safely visible labels; have the designer verify actual demand.
- Note loads that start together and any pumps, motors or variable-duty equipment.
- Ask how reserve, temperature and control settings affect available output.
For first-time integration, read the battery retrofit comparison. If a battery already appears to behave strangely, read monitoring warning signs before assuming its capacity is too small. The site-assessment worksheet helps record goals for the broader solar and battery design without inventing a recommended size.
Common questions
Can a full battery still draw electricity from the grid?
Yes. Loads can exceed the battery’s power limit, or reserve and operating settings can restrict discharge. A full state-of-charge reading alone does not establish available output.
Sources and scope
Source check: 5 October 2026. General educational information, not an electrical design or a site assessment. Product instructions, local rules and contract terms must be checked for your circumstances.
- Australian Government — Batteries
Usable capacity versus power; AC/DC coupling; backup requires configuration; site restrictions; warranty and management questions.
Scope: Australia. Source date: Includes program information commencing 1 July 2025; page date not displayed.
- Australian Government — Monitor your solar system
Generation versus usage monitoring; extra measurement devices; app connectivity; battery operating configuration.
Scope: Australia. Source date: No publication date displayed.
Discuss your project or system
Share your goals and the information you have collected. Ask what assessment is appropriate for your circumstances.